中文字幕一区二区三区四区无码视频_中文字幕韩国精品无码一区在线观看_无码网站免费在线观看中文字幕_人妻精品久久久久中文字幕一区二区三区

Contact Us

Process 220V AC Cooling Fan run

Date: 2015-4-13   Click: 1523 Times

1, "220V AC Cooling Fan" fans have found abnormal sound during operation, the motor severe fever, live shell, switch trip, you can not start and so on, should immediately stop checking. To ensure safety, do not allow the fan running repairs, maintenance should be carried out after the commissioning of five minutes or so, confirming that no anomalies start running again.
2, according to the environmental conditions from time to time under "220V AC Cooling Fan" to supplement or replace the bearing grease (motor enclosed bearing service life without replacing the grease), to ensure that the fan is running in good lubrication, refueling less than 1000 hours / closure of bearings and motor bearings, fuel zl-3 with lithium grease filling 1/3 of the bearing inner and outer rings, running short of oil is strictly prohibited.
3, "220V AC Cooling Fan" should be stored in a dry environment, avoiding motor damp. Fans at the open storage, proper defensive measures. In the storage and handling process should prevent the fan bump avoid damage to the fan.

Back to: Industry news

+86-0769-83660708

Home Product News Contact